- Current Ranges 60 A / 600 A / 6000 A ACRMS
- Output Sensitivity (AC coupled) 50 mV /5mV / 0.5mV per A
- Load Impedance 100 kOhm minimum
- Accuracy (at 25°C) ±1% of range (45 – 65 Hz)
- Linearity (10% to 100% of range) ±0.2% of reading
- Noise 8mV ACRMS (60 A) 2 mV ACRMS (600/6000A)
- Frequency Range 10 Hz to 50 kHz (- 3 dB)
- Phase Error <, ±1º (45 – 65Hz), ±10º (at 20 kHz)
- Position Sensitivity (with cable >, 25mm from the coupling) ±2% of range
- External field (with cable >, 200mm from the head) ±1% of range
- Power Supply 2 x AA MN 1500 LR6 alkaline 400 Hours, low battery indicator or dedicated ext power supply
- Temperature Coefficient ±0.08% of reading per C
- Working Voltage (see Safety Standards section) 600 V ACRMS or DC
- Head Cable length (double insulated) 610mm (24”) I6000s Flex-24, 915mm (36”) I6000s Flex-36
- Head Cable Diameter 14.3 mm
- Head Bend Radius 38.1 mm
- Cable length (head to electronics) 2 meters
- Output Connection 0.5 m cable terminated with safety BNC connector
- Operating Temperature Range -20 to 90 °C (head) -20 to 85 °C (electronics)
- Storage Temperature Range -40 to 105 °C (head) -20 to 85 °C (electronics)
- Operating Humidity 15% to 85% (non condensing)
- Weight 180 g (head), 190 g (electronics)
>
Each Unit Includes
- 4mm safety plug adaptor
Reviews
Returns Policy
We accept returns within 30 days of delivery. To qualify, items must be unused, in their original condition, and returned with all original packaging and accessories.
Once we receive and inspect the returned item, we will process your refund within 7 business days. Refunds will be issued to the original payment method.
Please note: Shipping costs are non-refundable unless the return is due to a defective or incorrect item.











by Jason Lee