- 4 channels
- Basic accuracy of ±0.02%*1 for power measurement (*1 PW6001 accuracy only. Instrument delivers accuracy of ±0.07% even after the current sensor accuracy has been added.)
- High noise resistance and stability (80 dB/100 kHz CMRR, ±0.01%/°C temperature characteristics)
- Accurate measurement even when the load is characterized by large fluctuations, TrueHD 18-bit resolution
- 10 ms data refresh while maintaining maximum accuracy (using a specially designed IC to make all measurements independently while performing simultaneous calculations.)
- DC basic accuracy of ±0.07%, which is key for stable, accurate efficiency measurement
- Broad frequency band and sampling that are 10 times better than those of legacy models
- Synchronize 2 units for up to 12 channels*2 in real time *2 Two 6-channel models can be connected with an optical connection cable (over a max. length of 500 m) to enable numerical and waveform synchronization
- Special triggers to enable waveform analysis and motor analysis without the need for an oscilloscope
- Wideband harmonic analysis up to the 100th order with a 1.5 MHz band